CTO

Immersion probes for temperature and oxidation measurement and metal sampling

Sidermag - CTO
Purpose:
Measurement of temperature, oxygen activity and sampling of molten metal
Application area:
Oxygen convectors, electric arc furnaces, induction furnaces, foundry ladles
Measurement Range:
from 1 to 2000 ppm O – metal oxidation
from 1000 to 1800 ° C – metal temperature
0,010 to 0,200 – carbon content
from 0.001 to 0.199% – aluminum content
Accuracy:
0 + 3 ° С at 1554 ° С
(from 5 to 10) mV (depending on the level of oxygen activity)
The shape of the selected form of metal:
Circle: diameter 34 mm, thickness 12 mm
Oval: diameter 34mm, length 42 mm, thickness 12 mm
Two-thickness: diameter 34 mm, length 60 mm, thickness 12 mm, thickness 4 mm
Spreader:
Without deoxidizer, aluminum, zirconium, titanium
Measurement time:
8 sec
Tube length:
from 100 to 2500 mm (other lengths are available upon request)
Slag cap:
Steel, aluminum, copper, cardboard
Spray protection:
Sand, fireproof fiber
Type NSH:
B, S, R

CTO immersion probe for measurement of temperature, oxygen content and sampling of molten metal – designed for simultaneous measurement of temperature, oxygen content and sampling of molten metals in oxygen converters, electric arc, induction and blast furnaces as well as in casting ladles of various types by short-term immersion (up to 10 seconds) in molten metal. CTO are compatible and interchangeable with all connection systems and commercially available devices. No adaptation is required to use CTO at your plant