- Products
- •
- Temperature measurement
- •
- Supertemp-SP
Supertemp
Immersion thermocouple single use anti-spatter

Purpose: |
Measuring of molten metal temperature |
Scope of use: |
Oxygen converters, electric arc furnace, induction furnace, blast furnace, foundry ladle |
Measuring range: |
from 300°С to 2020°С |
Precision: |
0 + 3°С by 1554°С |
Measuring time: |
4 sec |
Tube length: |
from 100 to 1800mm (optional another length possible) |
Dross cover: |
Steel, without cover, copper, aluminum |
Splash protection: |
Sand, fire resistant fiber |
NSC (nominal static characteristic) type: |
B, S, K, R |
Supertemp immersion thermocouples with protection against metal splashes Supertemp – designed to measure temperature of molten metals in induction furnaces as well as in casting ladles of various types by short-term immersion (up to 6 seconds) in molten metal. Allow user to safely measure the temperature due to special cover preventing spattering of metal. Supertemp are compatible and interchangeable with all connection systems and commercially available devices. No adaptation is required to use Supertemp at your plant