CTO
Immersion probes for temperature and oxidation measurement and metal sampling
Purpose: |
Measurement of temperature, oxygen activity and sampling of molten metal |
Application area: |
Oxygen convectors, electric arc furnaces, induction furnaces, foundry ladles |
Measurement Range: |
from 1 to 2000 ppm O – metal oxidation from 1000 to 1800 ° C – metal temperature 0,010 to 0,200 – carbon content from 0.001 to 0.199% – aluminum content |
Accuracy: |
0 + 3 ° С at 1554 ° С (from 5 to 10) mV (depending on the level of oxygen activity) |
The shape of the selected form of metal: |
Circle: diameter 34 mm, thickness 12 mm Oval: diameter 34mm, length 42 mm, thickness 12 mm Two-thickness: diameter 34 mm, length 60 mm, thickness 12 mm, thickness 4 mm |
Spreader: |
Without deoxidizer, aluminum, zirconium, titanium |
Measurement time: |
8 sec |
Tube length: |
from 100 to 2500 mm (other lengths are available upon request) |
Slag cap: |
Steel, aluminum, copper, cardboard |
Spray protection: |
Sand, fireproof fiber |
Type NSH: |
B, S, R |
CTO immersion probe for measurement of temperature, oxygen content and sampling of molten metal – designed for simultaneous measurement of temperature, oxygen content and sampling of molten metals in oxygen converters, electric arc, induction and blast furnaces as well as in casting ladles of various types by short-term immersion (up to 10 seconds) in molten metal. CTO are compatible and interchangeable with all connection systems and commercially available devices. No adaptation is required to use CTO at your plant