CET

Immersion probes for temperature measurement and sampling

Sidermag - CET
Purpose:
Temperature measurement and sampling of molten steel
Application area:
Oxygen convectors, electric arc furnaces, induction furnaces, foundry ladles
Measurement Range:
from 1000 to 2000 ° C – metal temperature
Accuracy:
0 + 3 °С at 1554 °С
The shape of the selected form of metal:
Circle: diameter 34 mm, thickness 12 mm
Oval: diameter 34mm, length 42 mm, thickness 12 mm
Two-thickness: diameter 34 mm, length 60 mm, thickness 12 mm, thickness 4 mm
Spreader:
Without deoxidizer, aluminum, zirconium, titanium
Measurement time:
8 sec
Tube length:
from 100 to 2500 mm (other lengths are available upon request)
Slag cap:
Steel, aluminum, copper, cardboard
Spray protection:
Sand, fireproof fiber
Type NSH:
B, S, R

Designed for simultaneous temperature measurement and sampling of molten metals in oxygen converters, electric arc, induction and blast furnaces as well as in casting ladles of various types by short-term immersion (up to 10 seconds) in molten metal. CET are compatible and interchangeable with all connection systems and commercially available devices. No adaptations are required to use CET at your plant.